Data Center Insulation Solutions
Data centers are among the most demanding building types when it comes to fire safety, thermal performance, structural durability and energy efficiency. From hyperscale campuses to colocation facilities, every component of the building envelope must contribute to operational resilience while helping reduce cooling demand and maintain efficient operating conditions.
FOAMGLAS® cellular glass insulation solutions are specifically designed for mission-critical infrastructure where long-term performance cannot be compromised. Thanks to their non-combustible composition, waterproof cellular glass structure and exceptional compressive strength, FOAMGLAS® systems provide reliable insulation for technical roofs, raised floor assemblies and other critical building applications.
With FM Approved roof systems, Euroclass A1 fire performance and thermal properties that remain stable throughout the building lifecycle, FOAMGLAS® helps data center owners and designers achieve energy efficiency, durability and risk reduction objectives while protecting high-value digital infrastructure.
WHY FOAMGLAS® FOR DATA CENTERS?
Data centers are among the most demanding infrastructures in terms of performance, safety and reliability. Their continuous operation places high demands on every building component to protect critical equipment, reduce operational risks and maintain long-term energy efficiency.
Thanks to its unique cellular glass structure, FOAMGLAS® provides an insulation solution designed to meet these requirements. Impermeable to water and water vapor, it retains its thermal performance over time without the risk of moisture absorption. Its dimensional stability and compressive strength enable it to withstand the substantial loads associated with technical installations in data centers over the long term.
In an environment where equipment availability is essential, fire safety is also a major concern. As a Euroclass A1 non-combustible insulation, FOAMGLAS® does not contribute to fire development, supporting the passive fire-safety strategy of the building envelope. Completely non-combustible, it helps protect the building envelope in the event of a fire, making it particularly suitable for critical infrastructure where risk management is a priority.
In addition to its technical performance, FOAMGLAS® helps improve building energy efficiency. Its thermal properties remain stable throughout the building’s service life, without settling or loss of performance, providing predictable thermal efficiency over the long term.
BUILDING ENVELOPE INSULATION SOLUTIONS
FOAMGLAS® insulation can also be specified across other key areas of the data center building envelope, including external walls, technical partitions, plant rooms and service areas. By providing a consistent combination of non-combustibility, moisture resistance and long-term thermal performance, FOAMGLAS® helps designers create resilient, energy-efficient facilities while maintaining a coherent insulation strategy throughout the entire infrastructure.
TECHNICAL ROOF SYSTEMS:
THE MOST CRITICAL AREA OF THE DATA CENTER
The roof of a data center is no longer a simple weatherproofing element. It has become a critical technical platform supporting HVAC units, cooling equipment, cable infrastructure, renewable energy systems and other mission-critical equipment. These loads create demanding structural and thermal requirements that conventional insulation materials often struggle to meet over time.
Designed specifically for these challenging environments, the FOAMGLAS® Compact Roof combines high compressive strength, permanent dimensional stability, water and vapour impermeability, and non-combustible insulation within a fully bonded roof system. Its ability to support heavy mechanical equipment while maintaining predictable thermal performance over time makes it an ideal solution for data center roofs, providing operators with confidence in lasting thermal efficiency and reliable protection throughout the building’s life cycle.
Compact roofs eliminate hidden air cavities and create a robust roofing assembly particularly suited to mission-critical facilities. FOAMGLAS® insulation can be fully bonded to the structural deck and waterproofing membrane, creating a monolithic system that limits moisture migration and reduces the risk of long-term degradation. For data centers where downtime is unacceptable, compact roof systems deliver enhanced reliability, predictable thermal performance and simplified maintenance.
RAISED FLOORS AND TECHNICAL FLOORING
Raised floors play a central role in modern data centers, supporting equipment loads while enabling efficient cable management and airflow distribution.
FOAMGLAS® insulation can be integrated into raised floor and technical flooring assemblies where high compressive strength and moisture resistance are required. Its cellular glass structure prevents water absorption, helping maintain thermal performance and protecting sensitive environments.
EXTERNAL FAÇADE
Designed for technical buildings, data halls and administrative spaces, ventilated façade systems provide an effective separation between outdoor conditions and the data center’s controlled environments. They contribute to the building’s energy efficiency while ensuring excellent envelope durability.
INTERNAL WALL
Where adjacent spaces operate under different temperature or humidity conditions, FOAMGLAS® can provide a thermally insulating and vapour-tight layer within the separating construction, helping maintain stable and controlled environmental conditions.
CEILING
Technical voids above suspended ceilings can accommodate extensive services and installations. FOAMGLAS® provides a non-combustible, water- and vapour-tight insulation layer that maintains its properties over time, supporting durable protection of these technically demanding spaces.
BELOW GROUND
Insulating below ground structures requires a material that can withstand challenging conditions, from high structural loads and persistent groundwater to brownfield sites and the need for consistent thermal performance.
THERMAL BRIDGE
Thermal bridges at load-bearing junctions can create localised heat losses and increase condensation risk. FOAMGLAS PERINSUL HL provides a load-bearing thermal break at critical junctions, helping maintain thermal continuity while transferring compressive loads.
CERTIFICATIONS AND WARRANTIES
Reduce Risk with FM Approved Roof Systems
Data center operators invest millions in digital infrastructure, making risk mitigation a primary design objective. FM Approved roof assemblies provide an additional level of confidence by demonstrating compliance with stringent performance criteria for wind uplift resistance and fire performance.
FOAMGLAS® insulation is used within numerous FM Approved roofing systems, helping designers and owners specify solutions that align with the requirements of highly protected risk facilities.
Long Lasting Performance
FOAMGLAS® cellular glass insulation is designed for long-term performance, with a reference service life of 100 years declared in the EPD. This long service life can reduce the need for insulation replacement and the associated consumption of materials and resources over the building life cycle.
For data centres, this is particularly relevant: fewer interventions in the building envelope also mean less disruption and risk around mission-critical infrastructure.
NEDERLANDS
InterXion Data Center
8000 m² | Compact Roof | FOAMGLAS T4+ | Amsterdam | 2009
4000 m² | Exterior Wall | FOAMGLAS READY BOARD | Amsterdam | 2009
Ziggo Data Center
9x 45 m² | Compact Roof | FOAMGLAS T4+ TAPERED | Netherlands | 2014
Rabobank Data Center
1600 m² | Compact Roof | FOAMGLAS T4+ | Netherlands | 2011
FRANCE
Data Center Argenteuil (95)
5000 m² | Compact Roof | FOAMGLAS T4+ | France | 2024
WODLI DATA CENTER ORANGE
2300 m² | Compact Roof | FOAMGLAS T4+ | France | 2024
DATA CENTER (91)
3334 m² | Compact Roof | FOAMGLAS T4+ | France | 2024
FAQ
Comment garantir la sécurité incendie dans un centre de données ?
La sécurité incendie est un enjeu crucial dans les centres de données, où la protection des équipements stratégiques et la garantie de la continuité d’activité sont essentielles. Le choix des matériaux de construction, en particulier celui de l’isolation, joue un rôle important dans la réduction des risques d’incendie. Une isolation incombustible contribue à limiter la propagation du feu et ne produit ni fumée ni gouttelettes enflammées en cas d’incendie. Associée à une enveloppe du bâtiment bien conçue, elle contribue à la résilience globale de l’installation et à la protection des actifs stratégiques.
Quel système d'isolation choisir pour la toiture d'un centre de données supportant des équipements techniques ?
Les toitures des centres de données supportent souvent des charges importantes provenant des unités de refroidissement, des installations électriques, des systèmes photovoltaïques et des équipements de maintenance. Le système d'isolation doit donc offrir une résistance élevée à la compression tout en garantissant des performances thermiques à long terme. Une solution résistante à l'humidité, indéformable dans le temps et conforme aux exigences de sécurité incendie contribue à assurer la durabilité de la toiture tout en réduisant les besoins d'entretien tout au long du cycle de vie du bâtiment.
Pourquoi les performances d'isolation à long terme sont-elles particulièrement importantes pour les centres de données ?
Les centres de données sont conçus pour fonctionner en continu, ce qui rend les interventions sur l'enveloppe du bâtiment potentiellement complexes et perturbatrices. Une solution d'isolation qui conserve ses propriétés au fil du temps contribue à réduire le risque de remplacement prématuré tout en garantissant des performances fiables à long terme de l'enveloppe du bâtiment.
CONTRIBUTION TO DATA CENTER ENERGY GOALS
As digital demand continues to grow, data centers must balance operational performance, energy management and sustainability. The building envelope plays an essential role in achieving these objectives by limiting heat loss and ensuring consistent performance over time.
Thanks to its hermetic cellular glass structure, FOAMGLAS® helps maintain the building’s energy efficiency throughout its lifecycle. Impermeable to water and water vapor, it reduces the risk of condensation that could affect insulation performance and the long-term durability of the building. Its dimensional stability also ensures no settlement and long-term retention of thermal resistance, even in the most demanding technical environments.
By preserving envelope performance over time, FOAMGLAS® helps operators optimize energy consumption, reduce maintenance needs and support sustainability objectives while controlling the building’s total cost of ownership.